Acetone CH3COCH3 NO.151


Performance

Measuring Range

0.05 to 0.8%

0.8 to 2.0%

Number of Pump Strokes

2

1

Correction Factor

1

2.5

Sampling Time

2 minutes per pump stroke

Detecting Limit

0.003% (n=2)

Color Change

Orange Dark green

Reaction Principle

CH3COCH3 + K2Cr2O7 + H2SO4 + H2O Cr2(SO4)3
Coefficient of Variation 10% (for 0.01 to 0.2 %), 5% (for 0.2 to 0.8 %)
Shelf Life 3 Years
Corrections for
temperature & humidity
Temperature correction is necessary
Store the tubes at cool and dark place.

Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Sulfur dioxide

500 ppm

Plus error

Produce green stain

Hydrogen sulfide

500 ppm

Plus error

Produce dark green

Alcohols, Esters, Ketones

-

Plus error

Produce dark green stain

Propane

0.2%

Yes

Produce dark green for whole layer

Aromatic HCs.

500 ppm

Plus error

Produce dark green

Other substance measurable with this detector tube

Substance

Correction Factor

Pump Strokes

Measuring Range

Cyclohexene

1.0

1

0.05 to 0.8%


Calibration gas generation Static gas dilution method


TLV-TWA TLV-STEL Explosive range
500ppm 750ppm 2.1 to 13%



Copyright(c) 2001 GASTEC CORPORATION. All rights reserved.