Ammonia NH3 NO.3HM

ƒCƒ‰ƒXƒg3HM


Performance

Measuring Range

0.05 to 1.6%

1.6 to 3.52%

Number of Pump Strokes

1

1/2

Correction Factor

1

2.2

Sampling Time

1 minute per pump stroke

Detecting Limit

0.01% (n=1)

Color Change

Pink Yellow

Reaction Principle

Ammonia neutralizes acids to discolor the indicator to yellow.

Coefficient of Variation 10% (for 0.05 to 0.4 %), 5% (for 0.4 to 1.6 ppm)
Shelf Life 3 Years
Corrections for
temperature & humidity
Unnecessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Hydrazine

-

Plus error

Discolor to yellow stain

Pyridine

-

Plus error

Discolor to yellow stain

Amines other than aromatic amines

-

Plus error

Discolor to yellow stain


Calibration gas generation High pressure gas cylinder method


TLV-TWA TLV-STEL Explosive range
25ppm 35ppm 15 to 28%


Copyright(c) 2001 GASTEC CORPORATION. All rights reserved.