| 2-Butanol | CH3CH2CH(OH)CH3 | NO.115 | |
|
|
|||

| Performance |
|
Measuring Range |
5 to 150 ppm |
|
Number of Pump Strokes |
3 |
|
Correction Factor |
1 |
|
Sampling Time |
3 minutes per pump stroke |
|
Detecting Limit |
1 ppm (n=3) |
|
Color Change |
Yellow |
|
Reaction Principle |
Sec-Butyl alcohol reduces potassium dichromate to form chromicsulfate, |
| Coefficient of Variation | 15% (for 5 to 50 ppm), 10% (for 50 to 150 ppm) |
| Shelf Life | 3 Years |
| Corrections for temperature & humidity |
Temperature correction is necessary |
| Store the tubes at cool and dark place. | |
| Possible coexisting substances and their interferences | (NOTE) |
|
Substance |
Concentration |
Interference |
Change color by itself |
|
Alcohols |
- |
Plus error |
Produce similar stain by themselves. |
| Calibration gas generation | Diffusion tube method | |
| TLV-TWA | TLV-STEL | Explosive range |
| 100ppm | - | 1.7 to 9.8% |
|
|
| Copyright(c) 2001 GASTEC CORPORATION. All rights reserved. |