1,3-Butadiene CH2:CHCH:CH2 NO.174

174


Performance

Measuring Range

50 to 800 ppm

Number of Pump Strokes

1

Correction Factor

1

Sampling Time

3 minutes per pump stroke

Detecting Limit

10 ppm (n=1)

Color Change

Pale yellow White

Reaction Principle

1,3-Butadiene reacts with palladium sulfate and ammonium
molybdate to to produce white compound.

Coefficient of Variation 10% (for 50 to 200 ppm), 5% (for 200 to 800 ppm)
Shelf Life 3 Years
Corrections for
temperature & humidity
Temperature correction is necessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Acetylene, Carbon monoxide

10 ppm

Plus error

Discolor to blue

Ammonia, Hydrogen cyanide

-

Plus error

Discolor to white

Hydrogen

20%

Plus error

Discolors to blue for whole layer

Hydrogen sulfide

10 ppm

Plus error

Discolors to black

Ethylene

1 ppm

Plus error

Discolors to blue

Styrene

-

Plus error

Discolor to pale blue


Other substance measurable with this detector tube

Substance

Correction Factor

Pump Strokes

Measuring Range

1,3-Pentadiene

5.0

1

250 to 4000 ppm


Calibration gas generation Static gas dilution method


TLV-TWA TLV-STEL Explosive range
2ppm - 2.0 to 12%


Copyright(c) 2001 GASTEC CORPORATION. All rights reserved.