| Chlorobenzene | C6H5Cl | NO.126L | |
|
|
|||

| Performance |
|
Measuring Range |
0.5 to 10 ppm |
10 to 43 ppm |
|
Number of Pump Strokes |
3 |
1 |
|
Correction Factor |
1 |
4.3 |
|
Sampling Time |
1.5 minutes per pump stroke |
|
|
Detecting Limit |
0.2ppm (n=3) |
|
|
Color Change |
Yellow |
|
|
Reaction Principle |
Chlorobenzene reacts with acid to produce hydrogen chloride |
|
| Coefficient of Variation | 10% (for 0.5 to 2 ppm), 5% (for 4 to 10 ppm) | |
| Shelf Life | 2 Years | |
| Corrections for temperature & humidity |
Temperature correction is necessary | |
| Store the tubes in the refrigerator to keep at 10oC (50oF) or below. | ||
| Possible coexisting substances and their interferences | (NOTE) |
|
Substance |
Concentration |
Result |
Change color by itself |
|
Chlorine, Hydrogen chloride, |
- |
Plus error |
Pale bluish purple |
| Calibration gas generation | Diffusion tube method | |
| TLV-TWA | TLV-STEL | Explosive range |
| 10ppm | - | 1.3 to 9.6% |
|
|
| Copyright(c) 2001 GASTEC CORPORATION. All rights reserved. |