Carbon monoxide CO NO.1H


Performance

Measuring Range

0.1 to 0.2%

0.2 to 5.0%

5.0 to10.0%

Number of Pump Strokes

2

1

1/2

Correction Factor

1/2

1

2

Sampling Time

1.5 minutes per pump stroke

Detecting Limit

0.02% (n=2)

Color Change

White Blackish brown

Reaction Principle

Carbon monoxide reduces iodine pentoxide to liberate
iodine, which is blackish brown.
Coefficient of Variation 10% (for 0.2 to 1.0 %), 5% (for 1.0 to 5.0 %)
Shelf Life 3 Years
Corrections for
temperature & humidity
Unnecessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Acetylene

0.3%

Plus error

Produce blackish brown stain.

Olefins

2/3 time

Plus error

Produce brown stain.

Butane

1%

Plus error

Produce pale brown for whole layer

Propane

20%

Plus error

No discoloration

Hexane

0.3%

Plus error

Produce pale brown for whole layer


Calibration gas generation High pressure gas cylinder method


TLV-TWA TLV-STEL Explosive range
25ppm - 12.5 to 74%