Carbon monoxide CO NO.1M


Performance

Measuring Range

0.05 to 0.1%

0.1 to 2.0%

2.0 to 4.0%

Number of Pump Strokes

2

1

1/2

Correction Factor

1/2

1

2

Sampling Time

3 minutes per pump stroke

Detecting Limit

0.01% (n=2)

Color Change

White Pale brown

Reaction Principle

Carbon monoxide reduces iodine pentoxide to liberate
iodine, which is blackish brown.
Coefficient of Variation 10% (for 0.1 to 0.5 %), 5% (for 0.5 to 2 %)
Shelf Life 3 Years
Corrections for
temperature & humidity
Unnecessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Acetylene

0.1%

Plus error

Produce blackish brown stain.

Olefins

2/3 time

Plus error

Produce pale brown stain.

Butane

0.3%

Plus error

Produce pale brown for whole layer

Propane

10%

Plus error

Produce pale brown for whole layer

Hexane

0.1%

Plus error

Produce pale brown


Other substance measurable with this detector tube

Substance

Correction Factor

Pump Strokes

Measuring Range

Gasoline

1

1

0.1 to 2%


Calibration gas generation High pressure gas cylinder method


TLV-TWA TLV-STEL Explosive range
25ppm - 12.5 to 74%