Chlorine Cl2 NO.8HH


Performance

Measuring Range

0.25 to 0.5%

0.5 to 10%

Number of Pump Strokes

1

1/2

Correction Factor

1/2

1

Sampling Time

1.5 minutesa per 1/2 pump stroke

Detecting Limit

0.05% (n=1)

Color Change

Reddish purple Yellow

Reaction Principle

Chlorine reacts with indicates indicator to yellow reaction products

Coefficient of Variation 10% (for 0.5 to 3 %), 5% (for 3 to 10 %)
Shelf Life 3 Years
Corrections for
temperature & humidity
Unnecessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Hydrogen chloride

-

Plus error

Produce pink stain

Nitric acid

-

Plus error

Produce pink stain


Other substance measurable with this detector tube

Substance

Correction Factor

Pump Strokes

Measuring Range

Hydrogen chloride

3.0

1/2

1.5 to 30 %


Calibration gas generation High pressure gas cylinder method


TLV-TWA TLV-STEL Explosive range
0.5ppm 1ppm -


Copyright(c) 2001 GASTEC CORPORATION. All rights reserved.