| O-Dichlorobenzene | C6H4Cl2 | NO.127 |
|
|
||

| Performance |
|
Measuring Range |
2.5 to 300 ppm |
|
Number of Pump Strokes |
2 |
|
Correction Factor |
1 |
|
Sampling Time |
1.5 minutes per pump stroke |
|
Detecting Limit |
1 ppm (n=2) |
|
Color Change |
White |
|
Reaction Principle |
o-Dichlorobenzene reacts with iodine pentoxide to liberate |
| Coefficient of Variation | 10% (for 2.5 to 10 ppm), 5% (for 30 to 300 ppm) |
| Shelf Life | 3 Years |
| Corrections for temperature & humidity |
Temperature correction is necessary |
| Store the tubes at cool and dark place. | |
| Possible coexisting substances and their interferences | (NOTE) |
|
Substance |
Concentration |
Interference |
Change color by itself |
|
Aromatic hydrocarbons |
- |
Plus error |
Produce brownish gray |
|
Acetylene |
0.2% |
- |
Produce pale brown |
|
Carbon monoxide |
0.1% |
- | |
|
Ethylene,Esters |
0.2% |
- | |
|
Hexane |
0.2% |
- | |
|
Alcohols, Ketones |
1% |
Plus error |
No discoloration |
| Other substance measurable with this detector tube |
|
Substance |
Correction Factor |
Pump Strokes |
Measuring Range |
|
m-Dichlorobenzene |
1.0 |
2 |
2.5 to 300 ppm |
| p-Dichlorobenzene | 1.0 | 2 | 2.5 to 300 ppm |
| Calibration gas generation | Diffusion tube method | |
| TLV-TWA | TLV-STEL | Explosive range |
| 25ppm | 50ppm | 2.2 to 12% |
|
|
| Copyright(c) 2001 GASTEC CORPORATION. All rights reserved. |