N,N-Dimethyl formamide HCON(CH3)2 NO.183


Performance

Measuring Range

0.8 to 2 ppm

2 to 30 ppm 30 to 90 ppm

Number of Pump Strokes

2

1 1/2

Correction Factor

0.4

1 3

Sampling Time

1.5 minutes per pump stroke

Detecting Limit

0.1 ppm (n=2)

Color Change

Pink Pale red

Reaction Principle

HCON(CH3)2 + NaOH R-NH2
2R-NH
2 + H2SO4 (R-NH2)2SO4
Coefficient of Variation 15% (for 2 to 10 ppm), 10% (for 10 to 30 ppm)
Shelf Life 3 Years
Corrections for
temperature & humidity
Temperature correction is necessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Amines

-

Plus error

Pale red

Ammomia

-

Plus error

Pale red

Hydrazine

-

Plus error

Pale red

Calibration gas generation Diffusion tube method


TLV-TWA TLV-STEL Explosive range
10ppm - 2.2 to 15.2%


Copyright(c) 2001 GASTEC CORPORATION. All rights reserved.