N,N-Dimethyl acetamide CH3CON(CH3)2 NO.184


Performance

Measuring Range

1.5 to 5 ppm

5 to 60 ppm 60 to 240 ppm

Number of Pump Strokes

4

2 1

Correction Factor

0.3

1 4

Sampling Time

2 minutes per pump stroke

Detecting Limit

0.5 ppm (n=4)

Color Change

Pink Pale yellow

Reaction Principle

CH3CON(CH3)2 + NaOH R-NH2
2R-NH
2 + H2SO4 (R-NH2)2SO4
Coefficient of Variation 15% (for 2 to 10 ppm), 10% (for 10 to 30 ppm)
Shelf Life 3 Years
Corrections for
temperature & humidity
Temperature correction is necessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Amines

-

Plus error

Pale yellow

Ammomia

-

Plus error

Pale yellow

Hydrazine

-

Plus error

Pale yellow

Calibration gas generation Diffusion tube method


TLV-TWA TLV-STEL Explosive range
10ppm - -