Ethyl acetate CH3CO2C2H5 NO.141


Performance

Measuring Range

0.1 to 1.5%

Number of Pump Stroke

1

Correction Factor

1

Sampling Time

2 minutes per pump stroke

Detecting Limit

0.01% (n=1)

Color Change

Orange Dark green

Reaction Principle

CH3CO2C2H5 + Cr6++ H2SO4 Cr3+

Coefficient of Variation

10% (for 0.04 to 0.3 %), 5% (for 0.3 to 1.5 %)

Shelf Life 3 Years
Corrections for
temperature & humidity
Temperature correction is necessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Sulfur dioxide

500 ppm

Plus error

Discolors green

Hydrogen sulfide

500 ppm

Plus error

Discolors dark green

Alcohols, Esters, Ketones

Plus error

Discolors dark green

Propane

0.2%

Plus error

Dark green (whole layer)

Aromatic HCs

500 ppm

Plus error

Discolors dark green


Other substance measurable with this detector tube

Substance

Correction

Pump Strokes

Measuring Range

Vinyl acetate

Factor: 0.6

1

0.02 to 0.9%


Calibration gas generation Static gas dilution method


TLV-TWA TLV-STEL Explosive range
400ppm - 2 to 11.5%


Copyright(c) 2001 GASTEC CORPORATION. All rights reserved.