| Ethyl acetate | CH3CO2C2H5 | NO.141L | |
|
|
|||

| Performance |
|
Measuring Range |
25 to 800 ppm |
|
Number of Pump Strokes |
2 |
|
Correction Factor |
1 |
|
Sampling Time |
3 minutes per pump stroke |
|
Detecting Limit |
5 ppm (n=2) |
|
Color Change |
Yellow |
|
Reaction Principle |
CH3CO2C2H5 + Cr6+ H2SO4 |
| Coefficient of Variation |
15% (for 25 to 200 ppm), 10% (for 200 to 800 ppm) |
| Shelf Life | 2 Years |
| Corrections for temperature & humidity |
Temperature correction is necessary |
| Store the tubes at cool and dark place. | |
| Possible coexisting substances and their interferences | (NOTE) |
|
Substance |
Concentration |
Interference |
Change color by itself |
|
Alcohols |
- |
Plus error |
Discolors greenish brown |
|
Ketones |
- |
Plus error |
Discolors greenish brown |
|
Esters |
- |
Plus error |
Discolors greenish brown |
|
Aromatic HCs |
- |
Plus error |
Discolors greenish brown |
| Calibration gas generation | Diffusion tube method | |
| TLV-TWA | TLV-STEL | Explosive range |
| 400ppm | - | 2 to 11.5% |
|
|
| Copyright(c) 2001 GASTEC CORPORATION. All rights reserved. |