Ethyl ether (C2H5)2O NO.161L


Performance

Measuring Range

10 to 400 ppm

400 to 1200 ppm

Number of Pump Strokes

2

1

Correction Factor

1

3

Sampling Time

4 minutes per pump stroke

Detecting Limit

2 ppm (n=2)

Color Change

Yellow Pale blue

Reaction Principle

Ethyl ether reduces cromic acid to produce pale blue discoloration.

Coefficient of Variation

10% (for 10 to 100 ppm), 5% (for 100 to 400 ppm)

Shelf Life 2 Years
Corrections for
temperature & humidity
Temperature correction is necessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Alcohols

-

Plus error

Produce pale blue discoloration

Esters

-

Plus error

Produce pale blue discoloration

Ketones

-

Plus error

Produce pale blue discoloration


Calibration gas generation Diffusion tube method


TLV-TWA TLV-STEL Explosive range
400ppm 500ppm 1.9 to 4 8%


Copyright(c) 2001 GASTEC CORPORATION. All rights reserved.