| Gasoline | CnHm | NO.101 | |
|
|
|||

| Performance |
|
Measuring Range |
0.015 to 0.03“ |
0.03 to 0.6% |
0.6 to 1.2% |
|
Number of Pump Strokes |
2 |
1 |
1/2 |
|
Correction Factor |
1/2 |
1 |
2 |
|
Sampling Time |
1 minute per pump stroke |
||
|
Detecting Limit |
0.003% (n = 2) |
||
|
Color Change |
Orange |
||
|
Reaction Principle |
Gasoline reduces potassium dichromate to form chromic sulfate, |
||
| Coefficient of Variation | 10% (for 0.03 to 0.1 %), 5% (for 0.1 to 0.6 %) | ||
| Shelf Life | 3 Years | ||
| Corrections for temperature & humidity |
Unnecessary | ||
| Store the tubes at cool and dark place. | |||
| Possible coexisting substances and their interferences | (NOTE) |
|
Substance |
Concentration |
Interference |
Change color by itself |
|
Acetylene |
3% |
Yes |
Produce dark brown to whole layer |
|
Propane |
0.2% |
Yes |
Produce dark brown to whole layer |
|
Aromatic HCs |
500 ppm |
Plus error |
Produce dark green |
|
Alcohols, Esters, Ethers |
- |
Plus error |
Produce dark green |
|
Halogenated HCs. |
5000 ppm |
Plus error |
Produce dark green |
|
Hydrogen sulfide |
500 ppm |
Plus error |
Produce dark green |
|
Sulfur dioxide |
500 ppm |
Plus error |
Produce green |
| Other substance measurable with this detector tube |
|
Substance |
Correction |
No. of Pump Strokes |
Measuring Range |
|
Heptane |
Factor: 1.0 |
1/2, 1 or 2 |
0.015 to 1.2% |
|
Isooctane |
Factor: 0.9 |
1 |
0.027 to 0.54% |
|
Octane |
Factor: 1.2 |
1 |
0.036 to 0.72% |
| Calibration gas generation | Static gas dilution method | |
| TLV-TWA | TLV-STEL | Explosive range |
| 300ppm | 500ppm | 1.4 to 7.6% |
|
|
| Copyright(c) 2001 GASTEC CORPORATION. All rights reserved. |