| Gasoline | CnHm | NO.101L | |
|
|
|||

| Performance |
|
Measuring Range |
30 to 1000 ppm |
1000 to 2000 ppm |
|
Number of Pump Strokes |
2 |
1 |
|
Correction Factor |
1 |
2 |
|
Sampling Time |
2 minutes per pump stroke |
|
|
Detecting Limit |
5 ppm (n=2) |
|
|
Color Change |
Brownish yellow |
|
|
Reaction Principle |
Propylene reduces potassium dichromate to form |
|
| Coefficient of Variation |
10% (for 30 to 300 ppm), 5% (for 300 to 1000 ppm) |
|
| Shelf Life | 3 Years | |
| Corrections for temperature & humidity |
Unnecessary | |
| Store the tubes at cool and dark place. | ||
| Possible coexisting substances and their interferences | (NOTE) |
|
Substance |
Concentration |
Interference |
Change color by itself |
| Hydrogen sulfide | - |
Plus error |
Dark brown |
|
Acetylene |
- |
Plus error |
Dark brown |
| Aromatic HCs | - | Plus error | Dark green |
| Esters, Ethers,Alcohols | - | Plus error | Dark green |
| Sulfur dioxide | - | Plus error | Dark green |
| Organic solvents ( |
- | Plus error | Dark green |
| Other substance measurable with this detector tube |
|
Substance |
Correction |
No. of Pump Strokes |
Measuring Range |
|
Allyl chloride |
Factor: 34 |
1/2 |
0.1 to 3.4% |
|
Heptane |
Factor: 1.0 |
1 or 2 |
30 to 2000 ppm |
|
Isobutene |
Factor: 22 |
1 |
0.07 to 2.2% |
| Calibration gas generation | Static gas dilution method | |
| TLV-TWA | TLV-STEL | Explosive range |
| 300ppm | 500ppm | 1.4 to 7.6% |
|
|