| Hydrogen cyanide | HCN | NO.12LL |
|
|
||

| Performance |
|
Measuring Range |
0.2 to 7 ppm |
|
Number of Pump Strokes |
2 |
|
Correction Factor |
1 |
|
Sampling Time |
2 minutes per pump stroke |
|
Detecting Limit |
0.05 ppm (n=2) |
|
Color Change |
Yellow |
|
Reaction Principle |
Hydrogen cyanide reacts with mercuric Chloride to form |
| Coefficient of Variation | 10% (for 0.2 to 2 ppm), 5% (for 3 to 7 ppm) |
| Shelf Life | 2 Years |
| Corrections for temperature & humidity |
Humidity correction is necessary |
| Store the tubes at cool and dark place. | |
| Possible coexisting substances and their interferences | (NOTE) |
|
Substance |
Concentration |
Interference |
Change color by itself |
|
Hydrogen sulfide |
1 ppm |
Plus error |
Red discoloration |
|
Sulfur dioxide |
1 ppm |
Plus error |
Red discoloration |
| Calibration gas generation | Permeation tube method | |
| TLV-TWA | TLV-STEL | Explosive range |
| - | C 4.7 ppm | 5.6 to 40% |
|
|
| Copyright(c) 2001 GASTEC CORPORATION. All rights reserved. |