Hydrogen chloride HCl NO.14L


Performance

Measuring Range

0.2 to 1 ppm

1 to 20 ppm

20 to 76 ppm

Number of Pump Strokes

2 to 5

1

1/2

Correction Factor

1/2 to 1/5

1

3.8

Sampling Time

1 minute per pump stroke

Detecting Limit

0.05 ppm (n=5)

Color Change

Yellow Pink

Reaction Principle

Hydrogen chloride reacts with indicator to produce pink stain.
HCl + Indicator Chemical reaction compound

Coefficient of Variation 10% (for 1 to 5 ppm), 5% (for 5 to 20 ppm)
Shelf Life 3 Years
Corrections for
temperature & humidity
Unnecessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Chlorine

1/2

Plus error

Produces pink stain

Nitric Acid

1/10

Plus error

Produces pink stain

Sulfur dioxide

10 times

Plus error

Produces pink stain

Nitrogen dioxide

5 times

Plus error

Produces pink stain


Calibration gas generation High pressure gas cylinder method


TLV-TWA TLV-STEL Explosive range
- C 5ppm -


Copyright(c) 2001 GASTEC CORPORATION. All rights reserved.