Hydrogen fluoride HF NO.17

17


Performance

Measuring Range

0.25 to 0.5ppm

0.5 to 20 ppm

20 to 100 ppm

Number of Pump Strokes

7

4

1

Correction Factor

1/2

1

5

Sampling Time

45 seconds per pump stroke

Detecting Limit

0.1ppm (n=7)

Color Change

Yellow Brownish Pink

Reaction Principle

Hydrogen fluoride reacts with indicator to produce brownish pink color.

HF + Indicator Chemical reaction compound

Coefficient of Variation

10% (for 0.5 to 5 ppm), 5% (for 5 to 20 ppm)

Shelf Life 3 Years
Corrections for
temperature & humidity
Humidity correction is necessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Hydrogen chloride, Nitric acid

1/5 time

Plus error

brownish pink stain

Chlorine, Nitrogen dioxide

1/10 time

Plus error

brownish pink stain


Other substance measurable with this detector tube

Substance

Correction Factor

Pump Stroke

Temperature

Absolute Humidity

Color Change

Fluorine

2.5

1

20oC (68oF)

9 mg/l

Produces brown stain

1.0

1

20oC (68oF)

3 mg/l


Calibration gas generation Permeation tube method


TLV-TWA TLV-STEL Explosive range
- C 3ppm -



Copyright(c) 2001 GASTEC CORPORATION. All rights reserved.