Hydrogen sulfide H2S NO.4LK

4LK


Performance

Measuring Range

1 to 2 ppm

2 to 20 ppm

20 to 40 ppm

Number of Pump Strokes

2

1

1/2

Correction Factor

1/2

1

2

Sampling Time

1 minute per pump stroke

Detecting Limit

0.25 ppm (n=2)

Color Change

White Brown

Reaction Principle

Hydrogen sulfide reacts with lead acetate to
form lead sulfide, which color is brown.

Coefficient of Variation 10% (for 2 to 6 ppm), 5% (for 6 to 20 ppm)
Shelf Life 3Years
Corrections for
temperature & humidity
Unnecessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Mercaptans

-

No effect

No discoloration

Sulfur dioxide

1/2 time

Plus error

No discoloration

Nitrogen dioxide

1/4 time

Minus error

No discoloration

Ozone

10 ppm

Bleaching

No discoloration


Calibration gas generation Permeation tube method


TLV-TWA TLV-STEL Explosive range
10ppm 15ppm 4.0 to 44%


Copyright(c) 2001 GASTEC CORPORATION. All rights reserved.