Isoamyl acetate CH3CO2(CH2)2CH(CH3)2
(i-CH3CO2C5H11)
NO.148


Performance

Measuring Range

10 to 200 ppm

Number of Pump Strokes

2

Correction Factor

1

Sampling Time

4 minutes per pump stroke

Detecting Limit

2 ppm (n=2)

Color Change

Yellow Pale blue

Reaction Principle

Isopropyl acetate reduces cromic acid to produce pale blue color.

Coefficient of Variation 15% (for 10 to 50 ppm), 10% (for 50 to 200 ppm)
Shelf Life Temperature correction is necessary
Corrections for
temperature & humidity
2 Years
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Alcohols

-

Plus error

Produce pale blue

Ketones

-

Plus error

Produce pale blue

Esters

-

Plus error

Produce pale blue


Calibration gas generation Diffusion tube method


TLV-TWA TLV-STEL Explosive range
100ppm - 1.0 to 7.5%


Copyright(c) 2001 GASTEC CORPORATION. All rights reserved.