Ozone O3 NO.18L


Performance

Measuring Range

0.025 to 0.05 ppm

0.05 to 0.6 ppm

0.6 to 3 ppm

Number of Pump Strokes

10

5

1

Correction Factor

1/2

1

5

Sampling Time

45 seconds per pump stroke

Detecting Limit

0.01 ppm (n=10)

Color Change

Blue White

Reaction Principle

Ozone reacts with indigo to form Isatin, which is white stain.
O3 + Indicator Chemical reaction product

Coefficient of Variation 10% (for 0.05 to 0.2 ppm), 5% (for 0.2 to 0.6 ppm)
Shelf Life 3 Years
Corrections for
temperature & humidity
Unnecessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Bromine

1 ppm

Plus error

Produces White stain

Hypochlorous acid

-

Plus error

Produces White stain

Nitrogen dioxide

1 ppm

Plus error

Produces White stain

Oxidant

-

Plus error

Produces White stain

Chlorine

10 ppm

Plus error
(Bleaching
)

Produces unclear
demarcation

Water vapor

100% relative humdity

Plus error


Calibration gas generation Ozone generater


TLV-TWA TLV-STEL Explosive range
0.1ppm - -