Phosphine PH3 NO.7L

7L


Performance

Measuring Range

0.15 to 0.3 ppm

0.3 to 5 ppm

Number of Pump Strokes

10

5

Correction Factor

1/2

1

Sampling Time

1 minute per pump stroke

Detecting Limit

0.04 ppm (n = 10)

Color Change

Pale yellow Purple

Reaction Principle

PH3 + Au compoundv Colloidal

Coefficient of Variation 10% (for 0.3 to 1 ppm), 5% (for 1 to 5 ppm)
Shelf Life 3 Years
Corrections for
temperature & humidity
Unnecessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Arsine

-

Plus error

Produces purple stain

Germane

-

Plus error

Produces purple stain

Hydrogen selenide

-

Plus error

Produces purple stain

Hydrogen sulfide

-

Plus error

Produces purple stain


Calibration gas generation High pressure gas cylinder method


TLV-TWA TLV-STEL Explosive range
0.3ppm 1ppm -



Copyright(c) 2001 GASTEC CORPORATION. All rights reserved.