Phosphine PH3 NO.7LA

7LA


Performance

Measuring Range

0.05 to 0.1 ppm

0.1 to 1.5 ppm

1.5 to 2.5 ppm

2.5 to 9.8 ppm

Pump Strokes

10

5

3

1

Correction Factor

1/2

1

1.7

6.5

Sampling Time

1.5 minutes per pump stroke

Detecting Limit

0.02 ppm (n = 10)

Color Change

Yellow Red

Reaction Principle

Phosphine reacts with mercuric chloride to produce
Hydrogen chloride to discolor the indicator to red.

Coefficient of Variation 10% (for 0.1 to 0.4 ppm), 5% (for 0.4 to 1.5 ppm)
Shelf Life 2 Years
Corrections for
temperature & humidity
Unnecessary
Store the tubes at cool and dark place.


Possible coexisting substances and their interferences (NOTE)

Substance

Concentration

Interference

Change color by itself

Arsine

1/10 time

Plus error

Produces red stain

Hydrogen chloride

-

No effect

No discoloration

Diborane

-

No effect

No discoloration


Calibration gas generation High pressure gas cylinder method


TLV-TWA TLV-STEL Explosive range
0.3ppm 1ppm -