| Vinyl acetate | CH3CO2CH:CH2 | NO.143 |
|
|
||

| Performance |
|
Measuring Range |
5 to 10 ppm |
10 to 100 ppm |
100 to 250ppm |
|
Number of Pump Strokes |
4 |
2 |
1 |
|
Correction Factor |
1/2 |
1 |
2.5 |
|
Sampling Time |
45 seconds per pump stroke |
||
|
Detecting Limit |
1 ppm (n=4) |
||
|
Color Change |
White |
||
|
Reaction Principle |
CH3CO2CH:CH2+C6H3(CH3)3+ H2S2O7 |
||
| Coefficient of Variation | 15% (for 10 to 20 ppm), 10% (for 20 to 100 ppm) | ||
| Shelf Life | 3 Years | ||
| Corrections for temperature & humidity |
Unnecessary | ||
| Store the tubes at cool and dark place. | |||
| Possible coexisting substances and their interferences | (NOTE) |
|
Substance |
Concentration |
Interference |
Change color by itself |
|
Aldehydes |
- |
Plus error |
Brown |
|
Ketones |
- |
Plus error |
Brown |
|
Ethylene |
1000ppm |
Plus error |
Yellow |
|
Vinyl chloride |
500ppm |
Plus error |
Yellow |
| Calibration gas generation | Diffusion tube method | |
| TLV-TWA | TLV-STEL | Explosive range |
| 10ppm | 15ppm | 2.6 to 13.4% |
|
|
| Copyright(c) 2001 GASTEC CORPORATION. All rights reserved. |